Power consumption in emergency operation | 8 W |
Working tension/Frequency of a network | AC 220-240 V/50-60 Hz |
Light source | LED |
Quantity of light-emitting diodes | 50 |
Operating time in emergency operation | 180 minutes |
Reaction time of emergency operation | <0,25 s |
Ni-CD battery | 3,6 V 2 800 mAh |
Battery charging time | 24 hours |
Size, mm | 333x110x77 |
Extent of protection | IP 65 |
Warranty period of service | 1 year |
The case from plastic, a plafond from polycarbonate with the lens. Supports the mode of both continuous, and changeable burning. The plafond is hermetically established by means of the fixing screws on a rubberized basis. Maximum protection against dust and moisture. |
Marking of connection and description of indicators: L – a phase, N – zero
Red indicator: burns – there is battery charging, doesn't burn – the mode of emergency work. |
Destination
Emergency lighting is designed for lighting of premises after hours. Emergency lighting, depending on the functions performed by them, are separated on evacuation and reserve.
Evacuation lighting can be of several types: the lighting of escape routes, emergency lighting hazardous area and anti-panic lighting (emergency lighting large areas).
On escape routes in addition to fixtures installed safety signs. First of all, evacuation signs showing the direction to emergency exits.
Application area
The premises of newly built and reconstructed buildings and structures for various purposes, places of production work outside of buildings, sites of industrial and agricultural enterprises, railways platforms of companies, external lighting of cities, towns and villages.
Setting
Internal or external mounting on the supporting surface.